default.asp
2051 W. Mountain Street
Glendale, CA 91201
866-781-8033
 
 
 
------------
  » Get FREE Products 
 

_Top Tools

  Safety Specs Bifocal Glasses
Lumber Wizard Metal Detector
Wall Wizard Stud Finder
Little Wizard Metal Detector
Measure Level
EZ Sand Sanding Blocks
Tool Kaddie Tool Carts
Strap & Carry
  _Specialty Products
  » Needle & Pin Sewing Detector
Secure Quick Disaster Products
Security Wands
Logging Detectors
Restaurant Metal Detector
Restaurant Metal Detector Wand

Birdshot Detector
Probe Metal Detector
Mail Scanner Metal Detector
Walk & Seek Metal Detector
  _Resources
» Distribution Services
» Manufacturer Reps

» Product Sheets


»
Get FREE Products

» Tech Support
» Tool Tips
» International Orders
» Press and News
» Image Library
» P.O.P Displays

Fine Tuning your Little Wizard
If your Little Wizard is not functioning correctly
please follow the instructions below.

(Nov. 01, 01)


$19.95

The New LITTLE WIZARD II
Precision Metal Detector For Locating Nails, Screws
And Other Metal Inside New and Recycled Wood.

Our Most Powerful Woodworking Detector
Instantly Locates Metal Inside Recycled Wood, New Wood or Timber

The Little Wizard can easily be fine-tuned or adjusted to your environmental conditions. Follow this procedure if your Little Wizard is displaying any of the following problems:
Doesn't Beep
Continuously Beeps
Works Intermittently
Doesn't Detect Metal
Cannot Adjust Working Point


First, make sure you are using a good battery. Battery problems account for the vast majority of problems seen with the Little Wizard.

1. Remove the battery cover and battery.
2. Remove the Cover Retaining Screw, located in the center of the underside of the unit. Use a small phillips head screwdriver (Figure 1).
3. Remove the cover, by lifting slowly from the battery end.
4. Locate the internal Fine Adjustment screw, located near the battery end of the circuit board. It is a round white knob with a cross shaped in the middle (for a phillips head screwdriver). (Figure 2)
5. Attach a good working battery.
6. Support the battery and the unit in one hand, and hold the unit away from any metal.
7. Turn the unit on by rotating the on/off/adjustment dial about half way.
8. If the unit IS beeping, rotate the internal adjustment screw counter-clockwise until the beeping just stops. (Figure 3)
9. If the unit IS NOT beeping, rotate the internal adjustment screw clockwise until the beeping starts, then back off just to where the beeping stops.
10. Test the unit by passing the detector head over a piece of visible metal.
11. Turn the unit off, and disconnect the battery.
12. Replace the cover: Connect the cover to the base at the detector head end first, then close the cover. Tighten the cover retaining screw.
13. Re-connect the battery and replace the battery cover.

The unit is now fine-tuned for your environmental conditions.
Figure 1. Cover Retaining Screw
Figure 2. Location of Internal Fine Adjustment Screw
Figure 3. Internal Fine Adjustment Screw - with battery connected, and unit turned on to half-way, rotate adjustment screw until the unit just stops beeping. (See instructions).


If, after following these instructions, your Little Wizard is still not working properly, call us at 888-346-3826 or email info@wizarddetectors.com.